RoofDek HLT 130-600
Specification details for RoofDek HLT 130-600

EN-Construction-Product-RoofDek structural liner tray - HLT 130-600 | Profile specification

Profile specification
Profile Material Gauge and finish Weight Load/Span maximum single span (mm) Load/Span maximum double span (mm) Minimum self curve (m) Minimum Factory curve (m) Cantillever (mm)
HLT 130/600 Steel 0.75 Interior Liner 9.57 4140 3850 - - 1050
Steel 1.00 Interior Liner 12.75 5080 5210 - - 1300
Steel 1.25 Interior Liner 15.95 5600 5820 - - 1400

The colour of the Interior Liner on all HLT profiles is RAL 9002.

If you have any questions or for further information click here to contact us.

EN-Construction-Product-RoofDek structural liner tray - HLT 130-600 | Download BIM objects

Download BIM objects

BIM: The way you want it

The DNA Profiler has been designed to allow you to access Tata Steel’s product information (3d parametric objects & data) how you want, when you want, to the level of detail you want, in the format you want.

Product Name Link
RoofDek HLT130/600 0.75 mm steel BIM DNA Profiler
RoofDek HLT130/600 0.75 mm steel perforated BIM DNA Profiler
RoofDek HLT130/600 1.00 mm steel BIM DNA Profiler
RoofDek HLT130/600 1.00 mm steel perforated BIM DNA Profiler
RoofDek HLT130/600 1.25 mm steel BIM DNA Profiler
RoofDek HLT130/600 1.25 mm steel perforated BIM DNA Profiler

In addition to our DNA Profiler, you can access our BIM content at BIMobject.com

Product Name Link
RoofDek HLT130/600 BIM Object

If you have any questions or for further information click here to contact us.

EN-Construction-Product-RoofDek structural liner tray | Design support

Design support

We maintain a friendly technical help desk which is freely available to all architects, engineers and contractors to assist with all aspects of RoofDek and liner tray design. The services we offer include:

Specification service - Our RoofDek team are able to provide a comprehensive specification service. Assistance in creating NBS specifications for RoofDek and trays can be provided to ensure the correct deck or tray is specified for the right application.

Design calculations & diaphragm design - To assist the specifier, the team are able to provide design calculations for live, dead, wind and snow drift loads and where required diaphragm design calculations.

Sound absorption and reduction - RoofDek perforated decking provides excellent sound absorption characteristics, our technical team can provide details of systems tested for both absorption and reduction. We also offer indicative acoustic calculations on differing build ups.

Roof Safety - Our technical department can provide details of non fragility performance of the RoofDek itself and the use of fall prevention and fall arrest systems on RoofDek roofs.

Inhouse CPD seminars - Primarily aimed at engineers and architects, these free seminars last around 50 minutes, ending with a question & answer session and are delivered by our experienced regional teams.

Topics include:

  • Structural roof deck in construction
  • Composite floor deck in construction
  • Sustainable steel cladding refurbishment solutions
  • Factory tour of Insulated panel lines

To request a CPD seminar please click here.

If you have any questions or for further information click here to contact us.