Profile Material Gauge and finish Weight Load/Span maximum single span (mm) Load/Span maximum double span (mm) Minimum self curve (m) Minimum Factory curve (m) Cantillever (mm)
HLT 145/600 Steel 0.75 Interior Liner 9.81 4310 3730 - - 1100
Steel 1.00 Interior Liner 13.08 5350 5400 - - 1350
Steel 1.25 Interior Liner 16.35 5950 6140 - - 1500

The colour of the Interior Liner on all HLT profiles is RAL 9002.

If you have any questions or for further information click here to contact us.

EN-Construction-Product-RoofDek structural liner tray - HLT 145-600 | Download BIM objects

Download BIM objects

BIM: The way you want it

The DNA Profiler has been designed to allow you to access Tata Steel’s product information (3d parametric objects & data) how you want, when you want, to the level of detail you want, in the format you want.

Product Name Link
RoofDek HLT145/600 0.75 mm steel BIM DNA Profiler
RoofDek HLT145/600 0.75 mm steel perforated BIM DNA Profiler
RoofDek HLT145/600 1.00 mm steel BIM DNA Profiler
RoofDek HLT145/600 1.00 mm steel perforated BIM DNA Profiler
RoofDek HLT145/600 1.25 mm steel BIM DNA Profiler
RoofDek HLT145/600 1.25 mm steel perforated BIM DNA Profiler

In addition to our DNA Profiler, you can access our BIM content at BIMobject.com

Product Name Link
RoofDek HLT145/600 BIM Object

If you have any questions or for further information click here to contact us.

EN-Construction-Product-RoofDek structural liner tray | Design support

Design support

We maintain a friendly technical help desk which is freely available to all architects, engineers and contractors to assist with all aspects of RoofDek and liner tray design. The services we offer include:

Specification service - Our RoofDek team are able to provide a comprehensive specification service. Assistance in creating NBS specifications for RoofDek and trays can be provided to ensure the correct deck or tray is specified for the right application.

Design calculations & diaphragm design - To assist the specifier, the team are able to provide design calculations for live, dead, wind and snow drift loads and where required diaphragm design calculations.

Sound absorption and reduction - RoofDek perforated decking provides excellent sound absorption characteristics, our technical team can provide details of systems tested for both absorption and reduction. We also offer indicative acoustic calculations on differing build ups.

Roof Safety - Our technical department can provide details of non fragility performance of the RoofDek itself and the use of fall prevention and fall arrest systems on RoofDek roofs.

Inhouse CPD seminars - Primarily aimed at engineers and architects, these free seminars last around 50 minutes, ending with a question & answer session and are delivered by our experienced regional teams.

Topics include:

  • Structural roof deck in construction
  • Composite floor deck in construction
  • Sustainable steel cladding refurbishment solutions
  • Factory tour of Insulated panel lines

To request a CPD seminar please click here.

If you have any questions or for further information click here to contact us.